Remote Sense |
The maximum load line drop is up to the full voltage rating of the supply. The drop in the load leads subtracts from the maximum voltage available for the load except as follows: maximum rated voltage is available at the load and voltage regulation specifications apply for line drops of<1V on DLM5-75 and DLM8-75, <2V for all other DLM600 models and DLM3K/4K models rated 5V to 16V, and <5V for all other DLM3K/4K models. |
Remote Programming |
Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5VDC, 0-10VDC, or 0-5kÙ |
Remote Monitoring |
Voltage or current can be monitored with userselectable ranges, scaled to 0-5 VDC or 0-10 VDC |
Operational Features |
Master/slave parallel operation, up to 4 units of the same model can be connected in parallel, with active current sharing control. Series operation, multiple units of the same model can be connected in series, limited by 300Vpk between either output terminal and chassis. |
Software |
IVI-COM, LabVIEW® or LabWindow®/CVI driver for Ethernet and IEEE-488.2 |
Regulatory Compliance |
CE Compliant: • Low Voltage Directive (73/23/EEC) using EN 61010-1, and • EMC Directive (89/336/EEC) using EN 61326 Certified to UL 61010-1, CSA C22.2 No. 61010.1 and IEC/EN 61010-1 | |
| |
|
|
Voltage and Frequency |
90-132 VAC or 180-264 VAC max, auto ranging, 47-63 Hz, single phase, 2-wire plus ground |
Current |
11A maximum at 115VAC, 6A maximum at 230 VAC |
Connector |
IEC 320 with detachable line cord |
Power Factor |
0.6, typical at full load; dependent on the impedance of the AC input. | |
| |
|
|
Line Regulation |
Voltage: 0.005% of V max + 2 mV Current: 0.01% of I max + 2 mA See table for input voltage variation over the AC input voltage range, with constant rated load. |
Load Regulation |
Voltage: 0.005% of V max + 2 mV Current: 0.02% of I max + 5 mA See table For 0-100% load variation, with constant nominal line voltage |
Transient Response |
500 ìs to steady-state output voltage (within 0.1% of Vmax) for 50-100% or 100-50% load change |
Stability |
±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature |
Efficiency |
84% typical at maximum output power; 82% typical for DLM 5-75 and DLM 8-75 |
Temperature Coefficient |
0.02%/°C of maximum output voltage, 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load. | |
| |
|
|
Dimensions |
Width: 8.5” (216 mm) |
|
Height: 1U or 1.75” (44 mm) |
|
Depth: 17” (432 mm) Option M6 depth 20” (508 mm) | |
| |
|
|
Weight |
9.7 lbs. (4.4 kg) |
Shipping Weight |
12.7 lbs. (5.8 kg) | |
| |
|
|
|
|
|
|
|
|
1 |
ANALOG-CONTROL Input |
14 |
EXTERNAL-OFF Input (+) |
2 |
EXTERNAL-OFF Return |
15 |
Auxiliary 5 VDC Output (+) |
3 |
OVP Programming Input |
16 |
OVP Resistance Programming Output |
4 |
REMOTE-CONTROL Status Output |
17 |
OVP Resistance Programming Return |
5 |
VOLTAGE-MODE Status Output |
18 |
FAULT Status Output |
6 |
Auxiliary 5 VDC Return |
19 |
Voltage Monitor Output |
7 |
Current Monitor Output |
20 |
Voltage Resistance Programming Return |
8 |
Voltage/Current Monitor Return |
21 |
Voltage Resistance Programming Output |
9 |
Voltage Programming Input |
22 |
Current Resistance Programming Output |
10 |
Current Programming Input |
23 |
Current Resistance Programming Return |
11 |
Not Used |
24 |
LOCAL-LOCKOUT Input |
12 |
V/I/OVP Programming Return |
25 |
OVP Status Output |
13 |
Not Used |
|
| | |
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
-
High Power Density: 600 watts in 1U (1.75 inches) high, half rack (8.5 inches) wide; no top or bottom clearance spacing required.
-
Near Linear Ripple & Noise: Ripple as low as 2.5mV rms, noise as low as 15mV p-p.
-
Remote Control • 16 bit programming through LXI -compliant Ethernet LAN / RS-232C (M130 • 12-bit programming through IEEE-488.2 / RS-232C (Option M9G) • Standard analog programming 0-5V, 0-10V, or 0-5kÙ. • isolated analog programming (option)
-
Pushbutton Preview: Overvoltage protection, voltage and current preview buttons allow viewing these set points at any time with or without the output enabled.
-
Active Down Programming: Standard internal circuitry to speed up response time to down programming changes.
-
Universal AC input
-
Easy master/slave paralleling with active current sharing
-
Software • IVI-com driver for M130 option • Labwindows CVI driver for M9G option • Labview driver for M9G option
-
5 Year Warranty
The DLM 600W series of programmable power supplies is designed to provide continuously variable output voltage and current for a broad range of applications in a compact 1U (1.75 inches) high, half-rack (8.5 inch) wide chassis.
With the use of Zero Voltage Switching (ZVS) technology, these supplies are able to achieve exceptionally low, near-linear ripple and noise rivaling larger and more expensive linear power supplies. In addition, the high efficiency and fast load transient response assure that the DLM is ideal for even the most demanding applications.
The DLM 600W models are ideal for high density multiple output rackmount requirements or low profile benchtop applications. Output voltages from 0-5VDC to 0-300VDC and currents from 0-2A to 0- 75A are available.
The cooling air intake is at the front and sides with exhaust at the rear and sides. Variable speed fans are controlled as a function of ambient air temperature and load, thus reducing acoustic noise and increasing fan life. This allows supplies to be stacked one directly on top of another without space in between, yielding maximum rackmount packing density and a wide operating temperature of 0-50° C. An optional rackmount kit is available to easily mount one or two units side-by-side.
The front panel layout makes the DLM600W series easy to use. Voltage and current can be set from individual 10-turn potentiometer knobs. Control push buttons include power on, output on, local/remote, voltage/ current preview and overvoltage protection preview. Set-point or actual voltage/ current values can be viewed on two 3-½ digit LED displays. The DLM600 can also be controlled through IEEE488.2 GPIB (option) or LXI-compliant Ethernet (option). Supplies can be connected in series or parallel. All models automatically accept any standard single phase input without manual set up.
|
|
|
|
|
|
|